An outdoor cabinet AC (air conditioner) refers to a cooling system designed for outdoor use, typically in cabinets or enclosures that house electronic or electrical equipment. These cabinets are often used to protect sensitive equipment from environmental factors such as heat, humidity, dust, and other elements. The outdoor cabinet AC unit helps maintain a controlled and optimal temperature inside the cabinet to ensure the proper functioning and longevity of the electronic components.

◆AC220V 50HZ power input
◆500W cooling capacity (optional configured with heater)
◆High efficiency rotary compressor:Reliable & energy saving
◆LED display:Parameters setting and operation display
◆IP55 High protection level:Application in outdoors perfectly
◆Wide operating temperature range:Adapt to all conditions
 
  • AC105-2/A05NA1E

  • Cytech

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

Panel Mounted AC 500W Outdoor Cabinet Air Conditioner 1700btu/h Product Video




Panel Mounted AC 500W Outdoor Cabinet Air Conditioner 1700btu/h Certificate


Thermal Management for Telecom Cabinets Certificate



Panel Mounted AC 500W Outdoor Cabinet Air Conditioner 1700btu/h Introduction


Outdoor cabinet air conditioner or outdoor cabinet coolingis actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.

 


Panel Mounted AC 500W Outdoor Cabinet Air Conditioner 1700btu/h Specifications

 

1) Technical parameter


 

Name

Cabinet Air Conditioner

Model

AC105-2/A05NA1E

Main power supply

1~220VAC±15% 50Hz 1 phase

Cooling capacity(Rated)

500W@L35/L35

Power consumption(Rated)

280W@L35/L35

Heating capacityoptional

500W

Air flow

120m3/h

Cooling current (rated/Max.)

1.4A/2.5A

Work temp. range

-40℃~+55℃

Noise

60dB(A)

IP Grade

IP55,NEMA 4,NEMA 4X

Net Weight

15KG

Refrigerant

R134a


Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃



2) Thermal cycle and air flow of cabinet air conditioner


Cabinet air conditioner cooling princple: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly

 

outdoor cabinet air conditioner cycle

 

Panel Mounted AC 500W Outdoor Cabinet Air Conditioner 1700btu/h Features


◆Cabinet Air Conditioner also can keep the dust and heat outside the cabinet,avoiding problems from using fan; 

◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;

◆Compact structure ,reasonable design and easy maintenance;

◆Digital temperature controller and high precision of temperature control;

◆The Cabinet Air Conditioner heating function and the hydrogen function is optional;

◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;

◆Dry contact alarm output,NO/NC optional;

◆LED display, all the settings can changed at the field

◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);

◆Cabinet Air Conditioner fits for harsh condition (T3), R134a refrigerant .


 

Cabinet air conditioner Flexibility


Cabinet Air Conditioner Cooling capacity ranges from 300w to 5000w

Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V

Cabinet Air Conditioner is idely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.

Remote monitoring system supported, communication protocol is RS485



More option for cabinet air conditioner


1) 220VAC 50HZ power cabinet air conditioner

 

Name

Model

Voltage

Nominal cooling capacity(W) (L35/L35)

Nominal cooling capacity(Btu/hr) (L35/L35)

Power consumption(W)(L35/L35)

IP Grade

Heater (W)(option)

Internal air flow (m3/h)

Refrigerant

Noise (dbA)

Cabinet air conditioner

CYAC103-2

220VAC 50Hz

300

1020

170

IP55,NEMA 4, NEMA 4X

500

100

R134a

56

Cabinet air conditioner

CYAC104-2

220VAC 50Hz

400

1360

215

IP55,NEMA 4, NEMA 4X

500

110

R134a

56

Cabinet air conditioner

CYAC105-2

220VAC 50Hz

500

1700

280

IP55,NEMA 4, NEMA 4X

500

120

R134a

56

Cabinet air conditioner

CYAC110-2

220VAC 50Hz

1000

3400

430

IP55,NEMA 4, NEMA 4X

1000

230

R134a

62

Cabinet air conditioner

CYAC112-2

220VAC 50Hz

1200

4080

498

IP55,NEMA 4, NEMA 4X

1000

240

R134a

62

Cabinet air conditioner

CYAC113-2

220VAC 50Hz

1300

4440

532

IP55,NEMA 4, NEMA 4X

1000

260

R134a

63

Cabinet air conditioner

CYAC115-2

220VAC 50Hz

1500

5100

600

IP55,NEMA 4, NEMA 4X

1000

300

R134a

63

Cabinet air conditioner

CYAC120-2

220VAC 50Hz

2000

6800

745

IP55,NEMA 4, NEMA 4X

1000

500

R134a

63

Cabinet air conditioner

CYAC125-2

220VAC 50Hz

2500

8500

846

IP55,NEMA 4, NEMA 4X

2000

560

R134a

63

Cabinet air conditioner

CYAC130-2

220VAC 50Hz

3000

10200

1240

IP55,NEMA 4, NEMA 4X

2000

720

R134a

63

Cabinet air conditioner

CYAC135-2

220VAC 50Hz

3500

11900

1360

IP55,NEMA 4, NEMA 4X

2000

1250

R134a

63

Cabinet air conditioner

CYAC150-2

220VAC 50Hz

5000

17000

2000

IP55,NEMA 4, NEMA 4X

2000

2300

R134a

63

 


2)220VAC 60HZ power cabinet air conditioner


Name

Model

Voltage

Nominal cooling capacity(W) (L35/L35)

Nominal cooling capacity(Btu/hr) (L35/L35)

Power consumption(W)(L35/L35)

IP Grade

Heater (W)(option)

Internal air flow (m3/h)

Refrigerant

Noise (dbA)

Cabinet air conditioner

CYAC103-2

220VAC 60Hz

300

1020

170

IP55,NEMA 4, NEMA 4X

500

100

R134a

56

Cabinet air conditioner

CYAC104-2

220VAC 60Hz

400

1360

215

IP55,NEMA 4, NEMA 4X

500

110

R134a

56

Cabinet air conditioner

CYAC105-2

220VAC 60Hz

500

1700

280

IP55,NEMA 4, NEMA 4X

500

120

R134a

56

Cabinet air conditioner

CYAC110-2

220VAC 60Hz

1000

3400

430

IP55,NEMA 4, NEMA 4X

1000

230

R134a

62

Cabinet air conditioner

CYAC112-2

220VAC 60Hz

1200

4080

498

IP55,NEMA 4, NEMA 4X

1000

240

R134a

62

Cabinet air conditioner

CYAC113-2

220VAC 60Hz

1300

4440

532

IP55,NEMA 4, NEMA 4X

1000

260

R134a

63

Cabinet air conditioner

CYAC115-2

220VAC 60Hz

1500

5100

600

IP55,NEMA 4, NEMA 4X

1000

300

R134a

63

Cabinet air conditioner

CYAC120-2

220VAC 60Hz

2000

6800

745

IP55,NEMA 4, NEMA 4X

1000

500

R134a

63

Cabinet air conditioner

CYAC125-2

220VAC 60Hz

2500

8500

846

IP55,NEMA 4, NEMA 4X

2000

560

R134a

63

Cabinet air conditioner

CYAC130-2

220VAC 60Hz

3000

10200

1240

IP55,NEMA 4, NEMA 4X

2000

720

R134a

63

Cabinet air conditioner

CYAC135-2

220VAC 60Hz

3500

11900

1360

IP55,NEMA 4, NEMA 4X

2000

1250

R134a

63

 

3)110V 60HZ power cabinet air conditioner


Name

Model

Voltage

Nominal cooling capacity(W) (L35/L35)

Nominal cooling capacity(Btu/hr) (L35/L35)

Power consumption(W)(L35/L35)

IP Grade

Heater (W)(option)

Internal air flow (m3/h)

Refrigerant

Noise (dbA)

Cabinet air conditioner

CYAC103-2

110VAC 60Hz

300

1020

170

IP55,NEMA 4, NEMA 4X

500

100

R134a

56

Cabinet air conditioner

CYAC104-2

110VAC 60Hz

400

1360

215

IP55,NEMA 4, NEMA 4X

500

110

R134a

56

Cabinet air conditioner

CYAC105-2

110VAC 60Hz

500

1700

280

IP55,NEMA 4, NEMA 4X

500

120

R134a

56

Cabinet air conditioner

CYAC110-2

110VAC 60Hz

1000

3400

430

IP55,NEMA 4, NEMA 4X

1000

230

R134a

62

Cabinet air conditioner

CYAC112-2

110VAC 60Hz

1200

4080

498

IP55,NEMA 4, NEMA 4X

1000

240

R134a

62

Cabinet air conditioner

CYAC113-2

110VAC 60Hz

1300

4440

532

IP55,NEMA 4, NEMA 4X

1000

260

R134a

63

Cabinet air conditioner

CYAC115-2

110VAC 60Hz

1500

5100

600

IP55,NEMA 4, NEMA 4X

1000

300

R134a

63



Other models of cabinet air conditioner 


Name

Specification

Air conditioner

AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W.

Heat exchanger

DC48V,40W/K-200W/K

Combined air conditioner & heat exchanger

AC220V 50HZ and DC48V

1500W&80W/K

TEC

DC48V, 200W-1200W

Fan

AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V

 


How to Choose a Cabinet Air Conditioner?


Proper cabinet cooling system selection is essential for maintaining a stable environment inside electrical enclosures. Overheating can cause equipment failure, reduced lifespan, and increased operational costs. Choosing the right cabinet air conditioner requires a detailed evaluation of several factors.


Key Considerations for Selecting a Cabinet Cooling Unit


1. Acceptable Temperature Range for Your Equipment

Maintaining an optimal temperature is critical for sensitive electronic components. The panel AC unit should effectively regulate heat within the specified range.


2. Heat Load of Equipment

The total heat dissipation inside the enclosure determines the required cooling capacity. A mismatched cabinet cooling unit may lead to inefficient temperature control.


3. The Highest Local Ambient Temperature

Outdoor cabinet air conditioners should be rated for peak ambient conditions to prevent performance degradation in extreme temperatures.


4. Noise Level

For installations in noise-sensitive areas, selecting a low-noise panel AC ensures minimal disturbance.


5. Future Expansion

Selecting a cabinet cooling system with sufficient cooling capacity allows for future equipment upgrades without compromising thermal management.

By considering these factors, you can choose an efficient cabinet air conditioner that meets your equipment's cooling demands.



Normative Standards for Cabinet Air Conditioner


Ensuring compliance with regulatory standards enhances safety and reliability. Key industry norms include:

  • GB 4208 – Enclosure Protection Class

  • GB 4706.1 – Safety of Household and Similar Electrical Appliances

  • GB 9237-2001 – Mechanical Refrigerating Systems Used for Cooling and Heating - Safety Requirements

  • GB/T 17626.8 – Electromagnetic Compatibility - Power Frequency Magnetic Field Immunity Test



Common Faults and Troubleshooting of Cabinet Cooling Systems


Fault State Possible Causes Solutions
The cabinet temperature is too high, but the air conditioner is not working. 1) Power failure.  2) Cooling set temperature is too high.  3) System fault. 1) Check power supply and circuit.  2) Adjust cooling temperature.  3) Contact professional maintenance.
The air conditioner is running, but cooling is ineffective. 1) Cooling capacity mismatch.  2) High ambient temperature.  3) System fault. 1) Upgrade or add another cabinet cooling unit.  2) Ensure operation within specified conditions.  3) Contact professional maintenance.
The air conditioner stops suddenly, but the electrical system is normal. 1) Cabinet temperature has reached the set point.  2) Other system faults. 1) Adjust temperature settings.  2) Contact professional maintenance.



Warranty Information for Cabinet Air Conditioner


Warranty Period

The standard warranty period is 12 months from operation start or a maximum of 18 months from delivery, depending on the agreement.


Warranty Coverage

During the warranty period, faults caused by panel AC unit quality issues will be repaired for free. However, the following cases are not covered:

  1. Warranty period has expired.

  2. Missing or unidentifiable product label.

  3. Damage due to improper installation, maintenance, or operation.

  4. Failures caused by external equipment or software.

  5. Unauthorized modifications or repairs.

  6. Damage caused by force majeure events such as fire, earthquakes, or floods.

Selecting a high-performance cabinet cooling system and ensuring regular maintenance will enhance equipment longevity and reliability.

Previous: 
Next: 

Consult Your Cytech Experts

Consult Your Cytech Experts
PROUDCTS
SUPPORT
QUICK LINKS
CONTACT US
    info@cytech.org.cn
   +86 13775296911
   weidun2013
    #5 Fuling Road, Zhonglou district, Changzhou, Jiangsu, China
COPYRIGHT © 2023 CHANGZHOU CHEN TONG YUAN COMMUNICATION EQUIPMENT CO.;LTD ALL RIGHTS RESERVED.