Model | Voltage | Cooling capacity(rated)(W) | Power consumption(W) | Heater (W) (option) | Weight(KG)Indoor unit/Outdoor unit | Noise (dbA) Indoor unit/Outdoor unit |
CY-A03NA | 3 Phase AC 380V±15% | 7500 | 2600 | 2000 | 135/30 | 55dB(A)/ 60dB(A) |
CY-A05NA | 3 Phase AC 380V±15% | 12500 | 4200 | 3000 | 200/46 | 57dB(A)/ 60dB(A) |
CY-A06NA | 3 Phase AC 380V±15% | 15000 | 5300 | 4000 | 215/55 | 58dB(A)/ 60dB(A) |
CY-A08NA | 3 Phase AC 380V±15% | 20000 | 6500 | 6000 | 231/116 | 60dB(A)/ 60dB(A) |
CY-A16NA | 3 Phase AC 380V±15% | 40000 | 11500 | 8000 | 475/230 | 65dB(A)/ 65dB(A) |
Features
A Server Room Air Conditioner plays a vital role in ensuring the efficient operation of IT infrastructure. Paired with Data Center Precision Air Conditioning, these systems offer tailored solutions for managing temperature, humidity, and airflow in critical environments. Below are the key features that make the Server Room Air Conditioner essential for maintaining optimal conditions in server rooms and data centers.
The Server Room Air Conditioner, in conjunction with Data Center Precision Air Conditioning, maintains consistent temperatures within a ±1°C range. This level of precision is crucial for protecting sensitive IT equipment from overheating, ensuring maximum performance and extending the lifespan of servers.
The Server Room Air Conditioner regulates humidity levels within a narrow band, preventing static discharge and corrosion. Combined with Data Center Precision Air Conditioning, this feature helps maintain an ideal environment for electronic components, preventing damage caused by excessive moisture or dryness.
Server Room Air Conditioner systems utilize features like hot aisle/cold aisle containment and variable-speed fans for optimized airflow. Data Center Precision Air Conditioning works with these technologies to ensure that airflow is directed efficiently, maintaining balanced temperatures throughout the server room.
Incorporating Data Center Precision Air Conditioning, Server Room Air Conditioner systems leverage energy-saving technologies such as free cooling, electronically commutated (EC) fans, and variable-speed compressors. These innovations reduce energy consumption, enhance cooling efficiency, and lower operational costs.
Reliability is critical in server room operations. The Server Room Air Conditioner incorporates redundancy features like N+1 or 2N configurations to ensure continuous cooling during system failures. This redundancy, paired with Data Center Precision Air Conditioning, helps maintain consistent performance even under challenging conditions.
As data center needs evolve, Server Room Air Conditioner systems offer scalable and modular designs that integrate seamlessly with Data Center Precision Air Conditioning solutions. This flexibility allows for easy expansion, adapting to growing cooling demands without a complete system overhaul.
Advanced monitoring systems in Server Room Air Conditioner units, integrated with Data Center Precision Air Conditioning, provide real-time data on temperature, humidity, and airflow. These intelligent controls enable automated adjustments to optimize performance and maintain ideal conditions.
To ensure a comfortable working environment, Server Room Air Conditioner systems operate quietly. When integrated with Data Center Precision Air Conditioning, these systems provide a noise-free solution, crucial in areas where personnel interact with sensitive equipment.
The Server Room Air Conditioner, when paired with Data Center Precision Air Conditioning, provides a highly efficient and reliable solution for cooling sensitive IT infrastructure. With features like precise temperature control, energy efficiency, and scalability, these systems ensure optimal conditions for equipment, reduce energy consumption, and minimize operational costs.
Application
Server rooms and data centers require precise environmental control to ensure optimal performance and protect sensitive equipment. The Server Room Air Conditioner plays a critical role in these applications, offering tailored solutions for temperature and humidity regulation. Below are the key applications of Server Room Air Conditioner:
Data centers generate substantial heat due to the high density of servers. The Server Room Air Conditioner is designed to maintain a consistent temperature within the room, preventing overheating that could lead to equipment failure. This precision cooling extends the lifespan of servers and ensures optimal operating conditions.
Both excessive and insufficient humidity levels can damage sensitive electronic components, causing issues such as corrosion or static electricity buildup. The Server Room Air Conditioner regulates humidity, ensuring that it stays within optimal ranges to prevent such damage and maintain equipment reliability.
Modern Server Room Air Conditioner systems incorporate advanced cooling technologies that optimize energy usage. These systems reduce operational costs by providing efficient cooling while supporting sustainable practices in data centers and server rooms.
Server Room Air Conditioner systems are designed to provide continuous operation, even during peak loads or challenging environmental conditions. This ensures that the server room remains cool and functional, minimizing the risk of downtime due to temperature fluctuations.
Data centers come in various sizes and configurations, each with unique cooling needs. The Server Room Air Conditioner can be scaled and customized to meet the specific demands of different server rooms, providing flexible and efficient cooling solutions tailored to each environment.
The Server Room Air Conditioner is essential for maintaining an optimal environment in server rooms and data centers. It ensures temperature regulation, humidity control, energy efficiency, continuous operation, and scalability, making it a vital component in the smooth and reliable operation of modern IT infrastructure.
How to order
Selecting the right Server Room Air Conditioner for your data center is essential to ensure optimal performance, reliability, and energy efficiency. This guide will help you make an informed decision by covering key factors to consider when choosing a cooling system for your server room.
Heat Load Assessment: Begin by calculating the total heat load generated by servers, storage devices, and other equipment. A Server Room Air Conditioner needs to match the cooling capacity to the heat output to prevent overheating and ensure consistent performance.
Room Size and Layout: The dimensions, airflow patterns, and rack configurations in your data center will affect how effectively the Server Room Air Conditioner can distribute cool air. Proper airflow management is crucial for minimizing hot spots and ensuring even cooling throughout the room.
Future Scalability: Consider the potential growth of your data center's computing needs. A well-chosen Server Room Air Conditioner will accommodate future expansion, preventing the need for costly upgrades later on.
Direct Expansion (DX) Systems: These systems are ideal for small to medium-sized data centers, using refrigerants for cooling. Server Room Air Conditioner units with DX technology provide efficient cooling for rooms with relatively lower heat loads.
Chilled Water Systems: For large data centers, chilled water systems are a better choice, as they rely on a continuous supply of chilled water for heat exchange, offering more effective cooling for high-density server environments.
In-Row Cooling: This method places cooling units directly next to the heat source, making it ideal for managing hot spots in high-density configurations, helping the Server Room Air Conditioner provide localized cooling where it's most needed.
Overhead Cooling: Overhead cooling systems manage airflow by utilizing ceiling-mounted units. This configuration works well for high-density racks, and Server Room Air Conditioner units can be customized for different layout needs.
Look for Server Room Air Conditioner units with energy-efficient features that will reduce operational costs:
Variable-Speed Fans and Compressors: These components adjust the cooling output based on real-time requirements, helping save energy and ensuring optimal performance.
Free Cooling Options: Many Server Room Air Conditioner systems include free cooling features, utilizing ambient air or water to lower energy consumption.
Advanced Controls: Intelligent monitoring and control systems allow for better optimization of cooling, ensuring that energy is used efficiently.
Humidity Regulation: Maintaining the right humidity levels is crucial for preventing static discharge and corrosion. A Server Room Air Conditioner with humidity control will help protect sensitive IT equipment from these environmental threats.
Air Filtration: Ensure that your Server Room Air Conditioner system includes high-quality air filters to protect your servers from dust and pollutants, which can degrade performance.
N+1 Redundancy: A Server Room Air Conditioner system with N+1 redundancy ensures that there's an additional cooling unit for every primary unit, guaranteeing continuous operation even if one unit fails.
Fail-Safe Mechanisms: Look for systems that include alarms, monitoring, and quick-switching capabilities to ensure reliability in the event of a failure.
Centralized Management: A Server Room Air Conditioner system that integrates with your building management systems (BMS) allows for centralized control and monitoring of temperature, humidity, and airflow.
Real-Time Alerts: Ensure the system can send real-time alerts to notify you of any abnormal conditions, allowing for swift responses to prevent damage.
Ease of Maintenance: Choose a Server Room Air Conditioner that features easy-to-access components and simplified maintenance routines, reducing downtime and the need for frequent service.
Service Availability: Verify that the manufacturer or vendor provides reliable local support and spare parts to ensure quick repairs and minimal disruption.
Initial Investment: While it's important to consider the upfront cost of equipment and installation, keep in mind that the most expensive system may not always provide the best long-term value.
Operational Costs: Evaluate ongoing operational costs, including energy consumption and maintenance expenses. A more energy-efficient Server Room Air Conditioner can offer significant savings over time.
Make sure that your Server Room Air Conditioner meets industry standards and certifications such as ASHRAE and ISO, ensuring reliability, safety, and efficient operation in a data center environment.
Finally, consulting with experienced engineers or data center cooling specialists is crucial to selecting the right Server Room Air Conditioner for your needs. These professionals can offer expert advice tailored to your specific data center requirements, ensuring that your cooling solution is efficient and future-proof.
Choosing the right Server Room Air Conditioner system requires a thorough understanding of your data center's current and future requirements. By focusing on scalability, energy efficiency, reliability, and maintenance, you can ensure a robust cooling solution that supports uninterrupted operations and long-term cost savings.
If you need further guidance or recommendations on specific systems, feel free to ask!