DC115-1
Cytech
Telecom, Battery, Integrated
IP 55, IP 65
1500W/5100BTU
| Availability: | |
|---|---|
Product Description
The DC1500W enclosure air conditioners use a closed-loop cooling system specifically designed for industrial cabinets where alarm function is critical.
The integrated alarm system monitors temperature and system status continuously, sending alerts if predefined thresholds are exceeded. This proactive protection ensures the safety of cabinet-installed electronics and reduces maintenance costs.
The DC-powered design allows stable operation in industrial facilities requiring high reliability, while the compact housing fits various industrial cabinet layouts.
Integrated alarm system for real-time fault and temperature alerts
Closed-loop cooling system for industrial cabinet protection
Designed as industrial enclosure air conditioners with alarm function
Stable DC-powered operation for continuous industrial performance
Intelligent temperature control with automatic regulation
Over-temperature, system fault, and protection mechanisms
Durable housing resistant to dust, moisture, and corrosion
Low-maintenance design for industrial installations
Flexible installation: side-mount or door-mount
Name | Eclosure Air Conditiners DC 1500 W |
Model | DC115-1 |
Main power supply | -48VDC(-DC44~-59V) |
Cooling capacity(Rated) | 1500W@L35/L35 |
Power consumption(Rated) | 320W@L35/L35 |
Heating capacity(optional) | 500W |
Air flow | 450m3/h |
Cooling current (rated/Max.) | 14.8A/19.0A |
Work temp. range | -40℃~+55℃ |
Noise | 65dB(A) |
IP Grade | IP55,NEMA 4,NEMA 4X |
Net Weight | 31KG |
Refrigerant | R134a |
Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃
Enclosure Air Conditioners Cooling Princple : the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.

Application
The DC1500W enclosure air conditioners are ideal for industrial cabinets where alarm function is required for safety and reliability, including:
Industrial control and automation cabinets
PLC and process control panels
Power distribution and electrical cabinets
Manufacturing equipment enclosures
Instrumentation and monitoring cabinets
Factory floor and industrial facility installations
Options
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
CYDC105-1 | -48VDC(DC-44~-59V) | 1700 | 180 | IP55,NEMA 4, NEMA 4X | 500 | 150 | R134a | 60 | |
CYDC106-1 | -48VDC(DC-44~-59V) | 2050 | 200 | IP55,NEMA 4, NEMA 4X | 500 | 150 | R134a | 60 | |
CYDC110-1 | -48VDC(DC-44~-59V) | 3400 | 295 | IP55,NEMA 4, NEMA 4X | 500 | 450 | R134a | 65 | |
CYDC115-1 | -48VDC(DC-44~-59V) | 1500 | 5100 | 495 | IP55,NEMA 4, NEMA 4X | 500 | 450 | R134a | 65 |
CYDC120-1 | -48VDC(DC-44~-59V) | 6800 | 710 | IP55,NEMA 4, NEMA 4X | 1000 | 700 | R134a | 69 | |
CYDC130-1 | -48VDC(DC-44~-59V) | 10200 | 1000 | IP55,NEMA 4, NEMA 4X | 1000 | 900 | R134a | 69 | |
CYDC140-1 | -48VDC(DC-44~-59V) | 13650 | 1350 | IP55,NEMA 4, NEMA 4X | 1000 | 1100 | R134a | 72 |
to be continued ,please contact with your sales expert.
Name | Specification |
| |
| |
| |
| |
|
Advantages&Why?
Whether in industrial plants or outdoor telecom sites, our AC units maintain stable temperatures, safeguarding critical electronics.
Prevents overheating, condensation, and equipment downtime with a trusted, high-performance cooling system.
Reduce operational costs without compromising on reliability, thanks to smart design and low energy consumption.
Decades years of experience
Global supply capability
Customized cooling solutions
Fast delivery and technical support
Widely used in telecom, utilities, transportation, and energy storage industries
Cooling capacity ranges from 300w to 5000w
Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V
Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.
Remote monitoring system supported, communication protocol is RS485

Our engineering team can recommend the right model based on:
Cabinet size
Heat load
Installation method
Environment
Voltage requirements
Contact us for datasheets, drawings, pricing, or OEM/ODM solutions.