Industrial Technology | Experts in Outdoor Enclosures and Thermal Management Solutions
R & D | Production | Sales
You are here: Home » Products » Thermal Management / Cabinet Ac Unit » 110V 60Hz Cabinet Air Conditioner » 110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel - 1000W 3440BTU

110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel - 1000W 3440BTU

Cytech's Air Conditioner for Electrical Panel or Outdoor Cabinet Air Conditioner achieves heat absorption refrigeration through compression refrigeration, transferring the heat emitted by the equipment inside the cabinet to the outside of the cabinet in a closed environment. The high temperature, dust and other dirty gases outside the cabinet will not enter the interior, thus solving a series of problems caused by fan heat dissipation. The interior of the cabinet can always maintain an ideal temperature environment of around 30 ℃, effectively ensuring the stability of electronic equipment.
◆AC110V 60HZ power input
◆1000W cooling capacity (optional configured with heater)
◆High efficiency rotary compressor:Reliable & energy saving
◆LED display:Parameters setting and operation display
◆IP55 High protection level:Application in outdoors perfectly
◆Wide operating temperature range:Adapt to all conditions
  • AC110-2/A10NA1E

  • Cytech

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel Product Video




110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel Certificate




110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel Introduction


Air Conditioner for electrical panel or outdoor cabinet air conditioner is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.



110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel Specifications


1.Technical parameter of Air Conditioner for Electrical Panel


Name Air Conditioner for Electrical Panel
Model AC110-2/A10NA1E
Main power supply 1~110VAC±15% 60Hz 1 phase
Cooling capacity(Rated) 1000W@L35/L35
Power consumption(Rated) 430W@L35/L35
Heating capacity(optional) 1000W
Air flow 230m3/h
Cooling current (rated/Max.) 3.9A/7.0A
Work temp. range -40℃~+55℃
Noise 60dB(A)
IP Grade IP55,NEMA 4,NEMA 4X
Net Weight 25KG
Refrigerant R134a

Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃



2. Thermal cycle and air flow of Air Conditioner for Electrical Panel


Air Conditioner for Electrical Panel Cooling Princple: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.


outdoor cabinet air conditioner cycle



110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel Features


◆Air Conditioner for Electrical Panel also can keep the dust and heat outside the cabinet,avoiding problems from using fan;

◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;

◆Compact structure ,reasonable design and easy maintenance;

◆Digital temperature controller and high precision of temperature control;

◆The Air Conditioner for Electrical Panel heating function and the hydrogen function is optional;

◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;

◆Dry contact alarm output,NO/NC optional;

◆LED display, all the settings can changed at the field

◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);

◆Air Conditioner for Electrical Panel fits for harsh condition (T3), R134a refrigerant .



110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel Flexibility


Cooling capacity ranges from 300w to 5000w

Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V

Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.

Remote monitoring system supported, communication protocol is RS485



More option for 110V 60HZ Outdoor Cabinet Air Conditioner for Electrical Panel


1.220VAC 50HZ power Air Conditioner for Electrical Panel



Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Air Conditioner for Electrical Panel CYAC103-2 220VAC 50Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Air Conditioner for Electrical Panel CYAC104-2 220VAC 50Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Air Conditioner for Electrical Panel CYAC105-2 220VAC 50Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Air Conditioner for Electrical Panel CYAC110-2 220VAC 50Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Air Conditioner for Electrical Panel CYAC112-2 220VAC 50Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Air Conditioner for Electrical Panel CYAC113-2 220VAC 50Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Air Conditioner for Electrical Panel CYAC115-2 220VAC 50Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
Air Conditioner for Electrical Panel CYAC120-2 220VAC 50Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
Air Conditioner for Electrical Panel CYAC125-2 220VAC 50Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
Air Conditioner for Electrical Panel CYAC130-2 220VAC 50Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
Air Conditioner for Electrical Panel CYAC135-2 220VAC 50Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63
Air Conditioner for Electrical Panel CYAC150-2 220VAC 50Hz 5000 17000 2000 IP55,NEMA 4, NEMA 4X 2000 2300 R134a 63



2.220VAC 60HZ power outdoor cabinet air conditioner


Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Air Conditioner for Electrical Panel CYAC103-2 220VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Air Conditioner for Electrical Panel CYAC104-2 220VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Air Conditioner for Electrical Panel CYAC105-2 220VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Air Conditioner for Electrical Panel CYAC110-2 220VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Air Conditioner for Electrical Panel CYAC112-2 220VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Air Conditioner for Electrical Panel CYAC113-2 220VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Air Conditioner for Electrical Panel CYAC115-2 220VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
Air Conditioner for Electrical Panel CYAC120-2 220VAC 60Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
Air Conditioner for Electrical Panel CYAC125-2 220VAC 60Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
Air Conditioner for Electrical Panel CYAC130-2 220VAC 60Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
Air Conditioner for Electrical Panel CYAC135-2 220VAC 60Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63



3.110V 60HZ power air conditioner for electrical panel


Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Air Conditioner for Electrical Panel CYAC103-2 110VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Air Conditioner for Electrical Panel CYAC104-2 110VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Air Conditioner for Electrical Panel CYAC105-2 110VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Air Conditioner for Electrical Panel CYAC110-2 110VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Air Conditioner for Electrical Panel CYAC112-2 110VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Air Conditioner for Electrical Panel CYAC113-2 110VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Air Conditioner for Electrical Panel CYAC115-2 110VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63



Other Air Conditioner for Electrical Panel


Name Specification
Air conditioner AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W.
Heat exchanger DC48V,40W/K-200W/K
Combined air conditioner & heat exchanger

AC220V 50HZ and DC48V

1500W&80W/K

TEC DC48V, 200W-1200W
Fan AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V



How to Choose an Air Conditioner for Electrical Panel?


1. Acceptable Temperature Range for Your Equipment


Ensure that the Air Conditioner for Electrical Panel can maintain the optimal temperature for your equipment. This is crucial to prevent overheating and protect sensitive components.


2. Heat Load of Equipment

Assess the heat load generated by your equipment. The air conditioning for electrical panels must be properly sized to handle the heat produced by the components, ensuring reliable operation.


3. Highest Local Ambient Temperature

The electrical enclosure cooling system must handle the highest local ambient temperature to ensure that the Air Conditioner for Electrical Panel operates effectively, even in extreme conditions.


4. Noise Level

In noise-sensitive environments, select a low-noise electronic enclosure cooling solution to ensure a quiet and efficient working environment.


5. Future Expansion

Consider future growth of your equipment and potential increase in heat load. Choose an Air Conditioner for Electrical Panel that can accommodate future needs and avoid costly upgrades later on.

By carefully evaluating these factors, you can select an air conditioning for electrical panels that perfectly suits your cooling needs.



Normative Standards for Outdoor Air Conditioner for Electrical Panels


1. GB 4208: Enclosure Protection Class

This standard ensures the electrical enclosure cooling system is protected against dust and water ingress, making it suitable for outdoor and harsh environments.


2. GB 4706.1: Safety of Household and Similar Electrical Appliances

Ensures the Air Conditioner for Electrical Panel meets electrical safety standards to prevent potential hazards in industrial settings.


3. GB 9237-2001: Mechanical Refrigerating Systems

Defines safety and performance requirements for air conditioning for electrical panels, ensuring efficient and secure cooling systems.


4. GB/T 17626.8: Electromagnetic Compatibility

Ensures that the electronic enclosure cooling system is immune to electromagnetic interference, protecting sensitive electrical equipment from disruption.



Fault Analysis and Solutions for Air Conditioner for Electrical Panel


Air Conditioner Not Running

  • Cause: Power failure or system malfunction.

  • Solution: Check the power supply and circuit; adjust the cooling temperature. If the issue persists, contact professional maintenance.


Insufficient Cooling

  • Cause: Mismatched cooling capacity or high ambient temperature.

  • Solution: Ensure the Air Conditioner for Electrical Panel is appropriately sized for the load. If necessary, consider adding another unit.


Sudden Shutdown

  • Cause: Cabinet temperature exceeds the cooling set temperature.

  • Solution: Adjust the cooling temperature and ensure the unit is used within the correct range. If the issue continues, consult professional maintenance.



Warranty and Coverage

  • Warranty Period: Typically 12-18 months, depending on the agreement.

  • Warranty Coverage: Covers product defects during the warranty period. Damage due to misuse, improper installation, or external factors such as fires or floods is not covered.



Conclusion

Choosing the right Air Conditioner for Electrical Panel involves considering factors such as temperature range, heat load, noise levels, and potential for future expansion. By selecting the proper electrical enclosure cooling system, you can ensure the safe and efficient operation of your electrical equipment. Adhering to industry standards and regular maintenance will prolong the life of your air conditioning for electrical panels and help maintain reliable performance.


Previous: 
Next: 

Consult Your Cytech Experts

Consult Your Cytech Experts
PROUDCTS
SUPPORT
QUICK LINKS
CONTACT US
    info@cytech.org.cn
   +86 13775296911
   weidun2013
    #5 Fuling Road, Zhonglou district, Changzhou, Jiangsu, China
COPYRIGHT © 2023 CHANGZHOU CHEN TONG YUAN COMMUNICATION EQUIPMENT CO.;LTD ALL RIGHTS RESERVED.