AC113-2/A13NA1E
Cytech
Telecom, Battery, Integrated
IP 55, NEMA 4, NEMA 4X
Half-embeded Mount, Door Mount
| Availability: | |
|---|---|
Product Description
Outdoor cabinets are exposed to extreme temperatures, solar radiation, humidity, and dust. Without effective thermal management, sensitive electronics can fail prematurely.
The CYTECH 1300W Cabinet Air Conditioner offers:
Provides 1300W (4440 BTU/H) cooling capacity to effectively remove heat generated by telecommunications, networking, battery management, and industrial control equipment.
Designed with IP55 protection and available NEMA 4/NEMA 4X configurations for challenging outdoor environments.
Suitable for operation in ambient temperatures ranging from -40°C to +55°C.
Integrated digital controller automatically regulates enclosure temperature while reducing energy consumption.
High-quality compressor and industrial-grade components ensure dependable long-term performance.

| Parameter | Value |
|---|---|
| Cooling Capacity | 1300W |
| Cooling Capacity | 4440 BTU/H |
| Refrigerant | R134a |
| Compressor Type | Rotary Compressor |
| Temperature Control | Digital Controller |
| Air Flow | According to configuration |
| Parameter | Value |
|---|---|
| Input Voltage | AC 220V/50Hz |
| Frequency | 50/60Hz |
| Power Consumption | Refer to technical datasheet |
| Protection Class | IP55 |
| Parameter | Value |
|---|---|
| Operating Temperature | -40°C to +55°C |
| Relative Humidity | Up to 95% RH |
| Installation | Door Mounted |
| Communication | Optional RS485 |
The premium compressor delivers stable cooling performance while minimizing energy consumption.
Real-time temperature display and programmable settings improve operational control.
Supports MODBUS-RTU protocol for remote monitoring and integration into network management systems.
Powder-coated galvanized steel housing provides excellent resistance against corrosion and weather exposure.
Uses environmentally friendly refrigerant while maintaining high cooling efficiency.
The sealed cooling system minimizes maintenance and ensures long-term reliability.
Enclosure Air Conditioner Cooling princple : the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly

The 1300W enclosure air conditioner is widely used across multiple industries.
Maintains stable operating temperatures for telecommunications equipment, fiber optic systems, routers, switches, and wireless communication devices.
Provides effective cooling for battery management systems and lithium battery storage applications.
Protects PLCs, VFDs, industrial computers, and control systems from excessive heat buildup.
Suitable for traffic signal systems, intelligent transportation infrastructure, and roadside control cabinets.
Maintains reliable operation of CCTV, security monitoring, and access control systems.
Ideal for solar power control cabinets, inverter enclosures, and energy management systems.
Outdoor enclosure air conditioners operate using a closed-loop refrigeration system.
The internal fan circulates hot air from inside the cabinet across the evaporator coil. Heat is absorbed and transferred through the refrigeration cycle to the condenser located on the external side of the unit. The cooled air is then returned to the enclosure while the heat is discharged to the surrounding environment.
This process ensures:
• Stable enclosure temperatures
• Protection against overheating
• Improved equipment lifespan
• Reduced system downtime
• Enhanced operational reliability
Using a dedicated enclosure air conditioner provides several advantages compared with passive ventilation solutions.
Maintains optimal operating temperatures for sensitive electronics.
Prevents heat-related component failures.
Reduces thermal stress on electronic devices.
Prevents dust, moisture, and contaminants from entering the enclosure.
Ensures stable operation regardless of outdoor weather conditions.
When choosing an enclosure cooling solution, consider:
Calculate the total heat generated by equipment installed inside the cabinet.
Evaluate maximum environmental temperatures in the installation area.
Larger enclosures may require higher cooling capacities.
Determine whether IP55, IP65, NEMA 4, or NEMA 4X protection is required.
Consider communication options such as RS485 and SNMP monitoring.
CYTECH specializes in outdoor enclosure thermal management solutions for global customers.
Over 15 years of enclosure and thermal management manufacturing experience.
Customized cooling solutions available for telecom, industrial, and energy storage applications.
Strict quality control processes and international certifications.
Products supplied to customers worldwide.
Professional technical assistance from design to deployment.
A 1300W unit is suitable for medium-sized telecom, industrial, and battery storage cabinets depending on the internal heat load.
Yes. It is designed to operate in ambient temperatures up to +55°C.
Yes. Optional RS485 communication with MODBUS-RTU protocol is available.
The standard design offers IP55 protection, with NEMA 4 and NEMA 4X options available.
Yes. Optional heating modules can be added for cold climate applications.
Yes. CYTECH provides OEM and ODM customization services for cabinet cooling solutions.
Telecommunications, battery energy storage, industrial automation, transportation, security, and renewable energy industries commonly use enclosure cooling systems.
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
220VAC 50Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
220VAC 50Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
220VAC 50Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
220VAC 50Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
220VAC 50Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
CYAC113-2 | 220VAC 50Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
220VAC 50Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 | |
220VAC 50Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 | |
220VAC 50Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 | |
220VAC 50Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 | |
220VAC 50Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 | |
220VAC 50Hz | 5000 | 17000 | 2000 | IP55,NEMA 4, NEMA 4X | 2000 | 2300 | R134a | 63 |
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
220VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
220VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
220VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
220VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
220VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
220VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
220VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 | |
220VAC 60Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 | |
220VAC 60Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 | |
220VAC 60Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 | |
220VAC 60Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
110VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
110VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
110VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
110VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
110VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
110VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
110VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
Name | Specification |
| |
| |
| |
| |
|
1. Power On, But the Cabinet Temperature is Too High and the Air Conditioner Isn’t Working:
Causes: Power failure, incorrect temperature settings, or system malfunction.
Solutions: Check the power supply, adjust the cooling temperature, or consult with professional maintenance.
2. The Air Conditioner Is Running, But the Cooling Effect Is Insufficient:
Causes: Mismatched cooling capacity, high ambient temperature, or system failure.
Solutions: Choose a more powerful air conditioner, ensure correct operational conditions, or contact a technician.
3. The Air Conditioner Stops Suddenly, but the Electric System is Normal:
Causes: The cabinet temperature has reached the set cooling temperature, or a system malfunction.
Solutions: Adjust the cooling settings or seek professional repair.
The warranty for your Outdoor Enclosure Air Conditioner typically lasts 12 months from the time the product is in use, or 18 months from the delivery date, depending on the agreement.
Warranty Coverage:During the warranty period, the manufacturer covers repairs for any product quality issues. However, the warranty does not cover:
Problems outside the warranty period
Lack of product labels
Damage due to improper installation, maintenance, or environmental factors
Failures caused by third-party equipment or software
Unauthorized modifications or repairs
Damage caused by natural disasters
By following these guidelines, you can ensure your electrical panel AC performs at its best, protecting your equipment and ensuring a reliable cooling solution for your outdoor enclosures.
In conclusion, when choosing an Outdoor Enclosure Air Conditioner, it’s crucial to assess factors such as heat load, local temperature conditions, noise level, and future expansion needs. Always choose a product that meets industry standards and is backed by a comprehensive warranty to ensure long-term performance and reliability.
Protect your telecom, battery storage, and industrial equipment with CYTECH outdoor enclosure air conditioners.
✅ OEM & ODM Customization
✅ Fast Delivery
✅ Global Technical Support
✅ Professional Engineering Team
Contact CYTECH today for pricing, technical consultation, and customized enclosure cooling solutions.