AC115-2/A15NA1E
Cytech
Availability: | |
---|---|
Product Description
Enclosure air conditioner or server rack enclosure cooling is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.
Name | Technical parameter |
Model | AC115-2/A15NA1E |
Main power supply | 1~220VAC±15% 50Hz 1 phase |
Cooling capacity(Rated) | 1500W@L35/L35 5100BTU/H @L35/L35 |
Power consumption(Rated) | 600W@L35/L35 |
Heating capacity(optional) | 1000W |
Air flow | 300m3/h |
Cooling current (rated/Max.) | 2.8A/4.0A |
Work temp. range | -40℃~+55℃ |
Noise | 65dB(A) |
IP Grade | IP55,NEMA 4,NEMA 4X |
Net Weight | 26KG |
Refrigerant | R134a |
Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃
Enclosure Air Conditioner Cooling Princple: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly
◆ Enclosure air conditioner also can keep the dust and heat outside the cabinet,avoiding problems from using fan;
◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;
◆Compact structure ,reasonable design and easy maintenance;
◆Digital temperature controller and high precision of temperature control;
◆The enclosure air conditioner heating function and the hydrogen function is optional;
◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;
◆Dry contact alarm output,NO/NC optional;
◆LED display, all the settings can changed at the field
◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);
◆Fit for harsh condition (T3), R134a refrigerant .
Enclosure air conditioner Cooling capacity ranges from 300w to 5000w
Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V
Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.
Remote monitoring system supported, communication protocol is RS485.
Name | Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
Enclosure air conditioner | CYAC103-2 | 220VAC 50Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 |
Enclosure air conditioner | CYAC104-2 | 220VAC 50Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 |
Enclosure air conditioner | CYAC105-2 | 220VAC 50Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 |
Enclosure air conditioner | CYAC110-2 | 220VAC 50Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 |
Enclosure air conditioner | CYAC112-2 | 220VAC 50Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 |
Enclosure air conditioner | CYAC113-2 | 220VAC 50Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
Enclosure air conditioner | CYAC115-2 | 220VAC 50Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
Enclosure air conditioner | CYAC120-2 | 220VAC 50Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 |
Enclosure air conditioner | CYAC125-2 | 220VAC 50Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 |
Enclosure air conditioner | CYAC130-2 | 220VAC 50Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 |
Enclosure air conditioner | CYAC135-2 | 220VAC 50Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
Enclosure air conditioner | CYAC150-2 | 220VAC 50Hz | 5000 | 17000 | 2000 | IP55,NEMA 4, NEMA 4X | 2000 | 2300 | R134a | 63 |
Name | Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
Enclosure air conditioner | CYAC103-2 | 220VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 |
Enclosure air conditioner | CYAC104-2 | 220VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 |
Enclosure air conditioner | CYAC105-2 | 220VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 |
Enclosure air conditioner | CYAC110-2 | 220VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 |
Enclosure air conditioner | CYAC112-2 | 220VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 |
Enclosure air conditioner | CYAC113-2 | 220VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
Enclosure air conditioner | CYAC115-2 | 220VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
Enclosure air conditioner | CYAC120-2 | 220VAC 60Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 |
Enclosure air conditioner | CYAC125-2 | 220VAC 60Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 |
Enclosure air conditioner | CYAC130-2 | 220VAC 60Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 |
Enclosure air conditioner | CYAC135-2 | 220VAC 60Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
Name | Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
Enclosure air conditioner | CYAC103-2 | 110VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 |
Enclosure air conditioner | CYAC104-2 | 110VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 |
Enclosure air conditioner | CYAC105-2 | 110VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 |
Enclosure air conditioner | CYAC110-2 | 110VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 |
Enclosure air conditioner | CYAC112-2 | 110VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 |
Enclosure air conditioner | CYAC113-2 | 110VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
Enclosure air conditioner | CYAC115-2 | 110VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
Name | Specification |
Air conditioner | AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W. |
Heat exchanger | DC48V,40W/K-200W/K |
Combined air conditioner & heat exchanger | AC220V 50HZ and DC48V 1500W&80W/K |
TEC | DC48V, 200W-1200W |
Fan | AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V |
Choosing the right Enclosure Air Conditioner is essential for ensuring the proper operation and protection of sensitive equipment housed within outdoor enclosures. The goal is to maintain an optimal internal temperature that prevents overheating and ensures reliable performance. Here's a comprehensive guide to help you select the right enclosure air conditioning solution.
The Enclosure Air Conditioner must be capable of maintaining a temperature within the ideal range for your equipment. This is critical for preventing component failure caused by overheating. Ensure that the cooling system can consistently provide the temperature control required for optimal operation.
Consider the total heat generated by the equipment within the enclosure. The enclosure AC should be sized appropriately to handle the heat load. Overestimating or underestimating the cooling capacity can lead to inefficiency and premature wear of both the system and the equipment.
The Enclosure Air Conditioner needs to be able to operate effectively in the local environment, which may include high ambient temperatures. Select a model with the capacity to cool in the worst-case local climate conditions to ensure continuous, reliable performance.
While cooling is important, it’s also essential to consider the noise generated by the enclosure air conditioning unit. In certain environments, especially where quiet operation is required, choosing a quieter model is crucial for maintaining a peaceful working environment.
If you expect to expand your equipment load in the future, plan for an Enclosure Air Conditioner with extra capacity. Upgrading the air conditioning system later can be costly and complicated, so it’s wise to choose a system that accommodates future needs.
By evaluating these factors, you can select an enclosure cooling solution that suits both your equipment and the environmental conditions.
When choosing an Enclosure Air Conditioner, it's important to ensure that it meets regulatory standards for safety and performance:
<GB 4208> – Enclosure Protection Class
<GB 4706.1> – Safety of household and similar electrical appliances
<GB 9237-2001> – Mechanical refrigerating systems used for cooling and heating – Safety requirements
<GB/T 17626.8> – Electromagnetic compatibility – Testing and measurement techniques – Power frequency magnetic field immunity test
These standards help ensure that the Enclosure Air Conditioner performs as expected and complies with safety regulations.
Possible Causes:
Power failure or no power
Cooling set temperature higher than cabinet temperature
System fault
Solutions:
Check power supply and electric circuit
Adjust cooling temperature to the required level
Contact professional maintenance for further inspection
Possible Causes:
The air conditioner’s capacity is insufficient for the load
Ambient temperature too high
Other system faults
Solutions:
Increase cooling capacity or add another Enclosure Air Conditioner
Ensure the system is within its operating range
Seek professional maintenance
Possible Causes:
Cabinet temperature equals or exceeds the set cooling temperature
System fault
Solutions:
Lower the cooling set temperature
Contact professional maintenance for system checks
The standard warranty period is 12 months from the product’s operational start date or up to 18 months from the delivery date, depending on the agreement with the manufacturer.
The warranty covers defects or failures caused by product quality issues during the warranty period. However, the warranty does not cover the following:
Failures occurring outside the warranty period
Missing product labels
Damage caused by improper installation, maintenance, or operation
Faults caused by external factors, such as other equipment or software issues
Unauthorized repairs or modifications
Damage caused by force majeure events, such as fires or floods
Choosing the right Enclosure Air Conditioner is crucial for maintaining optimal conditions inside your enclosures. By carefully evaluating factors like heat load, local ambient temperature, noise levels, and future expansion, you can ensure that your enclosure cooling system meets your equipment's specific needs. Additionally, adhering to industry standards and understanding potential faults can help maintain your system's performance and longevity. With the right Enclosure Air Conditioner, you can ensure efficient, reliable cooling for your sensitive equipment in any environment.