AC120-2/A20NA1E
Cytech
Availability: | |
---|---|
Product Description
Enclosure air conditioners is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.
Name | Enclosure Air Conditioners |
Model | AC120-2/A20NA1E |
Main power supply | 1~220VAC±15% 50Hz 1 phase |
Cooling capacity(Rated) | 2000W@L35/L35 |
Power consumption(Rated) | 745W@L35/L35 |
Heating capacity(optional) | 1000W |
Air flow | 500m3/h |
Cooling current (rated/Max.) | 3.8A/5.0A |
Work temp. range | -40℃~+55℃ |
Noise | 69dB(A) |
IP Grade | IP55,NEMA 4,NEMA 4X |
Net Weight | 30KG |
Refrigerant | R134a |
Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃
Enclosure Air Conditioners Cooling Princple : the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly
◆Enclosure Air Conditioners also can keep the dust and heat outside the cabinet,avoiding problems from using fan;
◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;
◆Compact structure ,reasonable design and easy maintenance;
◆Digital temperature controller and high precision of temperature control;
◆The heating function and the hydrogen function is optional;
◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;
◆Dry contact alarm output,NO/NC optional;
◆LED display, all the settings can changed at the field
◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);
◆Fit for harsh condition (T3), R134a refrigerant .
Cooling capacity ranges from 300w to 5000w
Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V
Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.
Remote monitoring system supported, communication protocol is RS485.
Name | Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
enclosure air conditioners | CYAC103-2 | 220VAC 50Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 |
enclosure air conditioners | CYAC104-2 | 220VAC 50Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 |
enclosure air conditioners | CYAC105-2 | 220VAC 50Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 |
enclosure air conditioners | CYAC110-2 | 220VAC 50Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 |
enclosure air conditioners | CYAC112-2 | 220VAC 50Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 |
enclosure air conditioners | CYAC113-2 | 220VAC 50Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
enclosure air conditioners | CYAC115-2 | 220VAC 50Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
enclosure air conditioners | CYAC120-2 | 220VAC 50Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 |
enclosure air conditioners | CYAC125-2 | 220VAC 50Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 |
enclosure air conditioners | CYAC130-2 | 220VAC 50Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 |
enclosure air conditioners | CYAC135-2 | 220VAC 50Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
enclosure air conditioners | CYAC150-2 | 220VAC 50Hz | 5000 | 17000 | 2000 | IP55,NEMA 4, NEMA 4X | 2000 | 2300 | R134a | 63 |
Name | Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
enclosure air conditioners | CYAC103-2 | 220VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 |
enclosure air conditioners | CYAC104-2 | 220VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 |
enclosure air conditioners | CYAC105-2 | 220VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 |
enclosure air conditioners | CYAC110-2 | 220VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 |
enclosure air conditioners | CYAC112-2 | 220VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 |
enclosure air conditioners | CYAC113-2 | 220VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
enclosure air conditioners | CYAC115-2 | 220VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
enclosure air conditioners | CYAC120-2 | 220VAC 60Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 |
enclosure air conditioners | CYAC125-2 | 220VAC 60Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 |
enclosure air conditioners | CYAC130-2 | 220VAC 60Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 |
enclosure air conditioners | CYAC135-2 | 220VAC 60Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
Name | Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
enclosure air conditioners | CYAC103-2 | 110VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 |
enclosure air conditioners | CYAC104-2 | 110VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 |
enclosure air conditioners | CYAC105-2 | 110VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 |
enclosure air conditioners | CYAC110-2 | 110VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 |
enclosure air conditioners | CYAC112-2 | 110VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 |
enclosure air conditioners | CYAC113-2 | 110VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 |
enclosure air conditioners | CYAC115-2 | 110VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
Name | Specification |
Air conditioner | AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W. |
Heat exchanger | DC48V,40W/K-200W/K |
Combined air conditioner & heat exchanger | AC220V 50HZ and DC48V 1500W&80W/K |
TEC | DC48V, 200W-1200W |
Fan | AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V |
Selecting the right Enclosure Air Conditioners is crucial for maintaining the performance and reliability of your equipment. The right electrical cabinet air conditioning unit ensures that your electrical systems operate within the desired temperature range, preventing overheating and prolonging their lifespan. To make an informed decision, consider the following factors:
Different equipment has specific temperature requirements. Ensure that the electrical cabinet AC unit can maintain the internal temperature within the optimal range for your equipment. Exceeding this range can lead to system failures, while too low of a temperature may waste energy.
The cooling capacity of the Enclosure Air Conditioners must match the heat load generated by your equipment. If the air conditioning unit cannot handle the heat, it will struggle to maintain an appropriate temperature, affecting equipment performance and reliability.
Consider the maximum ambient temperature in your operating environment. The electrical cabinet air conditioning system should be capable of operating efficiently under these high-temperature conditions. If the unit is unable to cope with local weather extremes, it may fail prematurely.
In noise-sensitive environments, selecting a quiet electrical cabinet air conditioning unit is essential. While all cooling systems generate some noise, there are options available that minimize sound output while still delivering adequate cooling.
If you anticipate expanding your equipment or increasing its cooling needs, consider selecting an Enclosure Air Conditioner that offers flexibility for future upgrades. Systems with scalable cooling capacities can accommodate future growth without the need for a complete replacement.
To ensure that your electrical cabinet air conditioning units meet safety and performance expectations, they should comply with the following standards:
GB 4208: Enclosure Protection Class – This standard specifies the level of protection against dust and water ingress, ensuring that your equipment remains safe from environmental damage.
GB 4706.1: Safety of Household and Similar Electrical Appliances – Ensures that the electrical cabinet air conditioning units meet safety requirements for electrical appliances.
GB 9237-2001: Mechanical Refrigerating Systems Safety Requirements – Specifies the safety standards for refrigerating systems used in Enclosure Air Conditioners.
GB/T 17626.8: Electromagnetic Compatibility – This standard tests electromagnetic compatibility to ensure that your electrical cabinet air conditioning unit does not interfere with nearby electrical equipment.
Possible Causes:
Power failure.
Cooling set temperature is higher than the cabinet temperature.
System malfunction.
Solutions:
Check the power supply and electrical circuits.
Set the cooling temperature appropriately.
Contact professional maintenance.
Possible Causes:
Cooling capacity insufficient for the load.
Ambient temperature too high.
System malfunction.
Solutions:
Add or upgrade the electrical cabinet air conditioning unit to match the load.
Ensure the unit is operating within the correct environmental range.
Contact professional maintenance.
Possible Causes:
Cabinet temperature exceeds the cooling set temperature.
Other system issues.
Solutions:
Adjust the cooling temperature as needed.
Contact professional maintenance.
The warranty for Enclosure Air Conditioners typically lasts for 12 months from the product’s operational start or a maximum of 18 months from the delivery date, depending on the agreement with the supplier.
During the warranty period, the company will repair any faults caused by product quality issues free of charge. However, the following situations are not covered:
Out-of-warranty issues.
Missing product labels.
Damage due to abnormal conditions, improper installation, maintenance, or operation.
Faults caused by other equipment or software.
Unauthorized modifications or disassembly.
Force majeure events such as fires, floods, or earthquakes.
By carefully considering these factors and ensuring compliance with normative standards, you can choose the right electrical cabinet air conditioning solution that meets your specific needs. This will help ensure the longevity, efficiency, and reliability of your electrical equipment.