Outdoor cabinet air conditioner or telecom cabinet cooling system achieves heat absorption refrigeration through compression refrigeration, transferring the heat emitted by the equipment inside the cabinet to the outside of the cabinet in a closed environment. The high temperature, dust and other dirty gases outside the cabinet will not enter the interior, thus solving a series of problems caused by fan heat dissipation. The interior of the cabinet can always maintain an ideal temperature environment of around 30 ℃, effectively ensuring the stability of electronic equipment.

◆AC220V 60HZ power input
◆1000W cooling capacity (optional configured with heater)
◆High efficiency rotary compressor:Reliable & energy saving
◆LED display:Parameters setting and operation display
◆IP55 High protection level:Application in outdoors perfectly
◆Wide operating temperature range:Adapt to all conditions
  • AC110-2/A10NA1E

  • Cytech

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

1000W Outdoor Cabinet Air Conditioner 3440BTU/H Product Video




1000W Outdoor Cabinet Air Conditioner 3440BTU/H Certificate


Thermal Management for Telecom Cabinets Certificate



1000W Outdoor Cabinet Air Conditioner 3440BTU/H Introduction


Outdoor cabinet air conditioner is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.



1000W Outdoor Cabinet Air Conditioner 3440BTU/H Specifications


1.Technical parameter of outdoor cabinet air conditioner


Name Outdoor cabinet air conditioner
Model AC110-2/A10NA1E
Main power supply 1~220VAC±15% 60Hz 1 phase
Cooling capacity(Rated) 1000W@L35/L35
Power consumption(Rated) 430W@L35/L35
Heating capacity(optional) 1000W
Air flow 230m3/h
Cooling current (rated/Max.) 2.0A/3.5A
Work temp. range -40℃~+55℃
Noise 60dB(A)
IP Grade IP55,NEMA 4,NEMA 4X
Net Weight 25KG
Refrigerant R134a

Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃



2. Thermal cycle and air flow of Outdoor Cabinet Air Conditioner 


Outdoor Cabinet Air Conditioner Cooling Princple: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.


 telecom cabinet cooling system cycle



1000W Outdoor Cabinet Air Conditioner 3440BTU/H Features


◆Outdoor Cabinet Air Conditioner also can keep the dust and heat outside the cabinet,avoiding problems from using fan;

◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;

◆Compact structure ,reasonable design and easy maintenance;

◆Digital temperature controller and high precision of temperature control;

◆The Outdoor Cabinet Air Conditioner heating function and the hydrogen function is optional;

◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;

◆Dry contact alarm output,NO/NC optional;

◆LED display, all the settings can changed at the field

◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);

◆Outdoor Cabinet Air Conditioner fits for harsh condition (T3), R134a refrigerant.



Outdoor Cabinet Air Conditioner Flexibility


Outdoor Cabinet Air Conditioner Cooling capacity ranges from 300w to 5000w

Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V

Outdoor Cabinet Air Conditioner is widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.

Remote monitoring system supported, communication protocol is RS485



More option for Outdoor Cabinet Air Conditioner 


1.220VAC 50HZ power outdoor cabinet air conditioner


Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Outdoor cabinet air conditioner CYAC103-2 220VAC 50Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Outdoor cabinet air conditioner CYAC104-2 220VAC 50Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Outdoor cabinet air conditioner CYAC105-2 220VAC 50Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Outdoor cabinet air conditioner CYAC110-2 220VAC 50Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Outdoor cabinet air conditioner CYAC112-2 220VAC 50Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Outdoor cabinet air conditioner CYAC113-2 220VAC 50Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Outdoor cabinet air conditioner CYAC115-2 220VAC 50Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
Outdoor cabinet air conditioner CYAC120-2 220VAC 50Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
Outdoor cabinet air conditioner CYAC125-2 220VAC 50Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
Outdoor cabinet air conditioner CYAC130-2 220VAC 50Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
Outdoor cabinet air conditioner CYAC135-2 220VAC 50Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63
Outdoor cabinet air conditioner CYAC150-2 220VAC 50Hz 5000 17000 2000 IP55,NEMA 4, NEMA 4X 2000 2300 R134a 63



2.220VAC 60HZ power outdoor cabinet air conditioner


Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Outdoor cabinet air conditioner CYAC103-2 220VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Outdoor cabinet air conditioner
CYAC104-2 220VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Outdoor cabinet air conditioner CYAC105-2 220VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Outdoor cabinet air conditioner CYAC110-2 220VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Outdoor cabinet air conditioner CYAC112-2 220VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Outdoor cabinet air conditioner CYAC113-2 220VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Outdoor cabinet air conditioner CYAC115-2 220VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
Outdoor cabinet air conditioner CYAC120-2 220VAC 60Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
Outdoor cabinet air conditioner CYAC125-2 220VAC 60Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
Outdoor cabinet air conditioner CYAC130-2 220VAC 60Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
Outdoor cabinet air conditioner CYAC135-2 220VAC 60Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63



3.110V 60HZ power outdoor cabinet air conditioner


Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Outdoor cabinet air conditioner CYAC103-2 110VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Outdoor cabinet air conditioner
CYAC104-2 110VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Outdoor cabinet air conditioner CYAC105-2 110VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Outdoor cabinet air conditioner CYAC110-2 110VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Outdoor cabinet air conditioner CYAC112-2 110VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Outdoor cabinet air conditioner CYAC113-2 110VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Outdoor cabinet air conditioner CYAC115-2 110VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63



Other Outdoor Cabinet Air Conditioner


Name Specification
Air conditioner AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W.
Heat exchanger DC48V,40W/K-200W/K
Combined air conditioner & heat exchanger

AC220V 50HZ and DC48V

1500W&80W/K

TEC DC48V, 200W-1200W
Fan AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V



How to Choose an Outdoor Cabinet Air Conditioner?


Selecting the right outdoor cabinet air conditioner is essential for maintaining stable equipment performance and extending service life. Below are the key factors to consider:


Acceptable Temperature Range for Your Equipment

Ensure the panel air conditioning unit can maintain a stable internal temperature to prevent overheating or freezing, protecting sensitive electronic components.


Heat Load of Equipment

Calculate the total heat dissipation inside the enclosure. Choose a cabinet air conditioning unit with a cooling capacity that matches or slightly exceeds the heat load for efficient thermal management.


The Highest Local Ambient Temperature

Outdoor cabinet air conditioners must withstand extreme weather conditions. Ensure the unit operates effectively even in the highest local ambient temperatures.


Noise Level

If the panel air conditioner is installed in a noise-sensitive environment, such as a telecom shelter, opt for low-noise models to minimize disturbances.


Future Expansion

Consider potential equipment upgrades. A cabinet air conditioning unit with slightly higher capacity can prevent frequent replacements and reduce long-term costs.

By evaluating these factors, you can select a cabinet climate control system that ensures optimal cooling efficiency and equipment protection.



Normative Standards for Cabinet Air Conditioning Units


GB 4208 – Enclosure Protection Class

Defines protection against dust, water, and other environmental factors.


GB 4706.1 – Safety of Household and Similar Electrical Appliances

Ensures safety compliance for electrical appliances.


GB 9237-2001 – Mechanical Refrigerating Systems Safety Requirements

Regulates safety standards for refrigeration systems used in cooling and heating applications.


GB/T 17626.8 – Electromagnetic Compatibility

Tests the system’s immunity to power frequency magnetic fields to prevent interference.



Common Faults and Troubleshooting


The Air Conditioner Is Not Working Despite High Cabinet Temperature



Possible Causes Solutions
Power failure or no power Check the power supply and circuit
Cooling set temperature is higher than cabinet temperature Adjust the cooling set temperature as needed
System fault Contact professional maintenance



The Air Conditioner Is Running but the Cooling Effect Is Poor


Possible Causes Solutions
Cooling capacity does not match the heat load Upgrade or add a cabinet air conditioning unit with higher capacity
Ambient temperature is too high Ensure the unit is operating within the recommended temperature range
Other system faults Contact professional maintenance



The Machine Stops Suddenly, but the Electrical System Is Normal


Possible Causes Solutions
Cabinet temperature has reached or exceeded the set cooling temperature Adjust the cooling temperature settings
System fault Contact professional maintenance




Warranty Policy


Warranty Period

The warranty period is 12 months from first operation or a maximum of 18 months from the delivery date, depending on the agreement with the company.


Warranty Coverage

If a failure occurs due to product defects within the warranty period, the company will provide free repairs, provided the product label is available.


Exclusions from Warranty


The warranty does not cover:

  • Failures occurring after the warranty period.

  • Missing product labels.

  • Damage due to improper installation, maintenance, or operation.

  • Issues caused by external factors such as incompatible software or power fluctuations.

  • Unauthorized disassembly or modifications.

  • Damage caused by natural disasters like fires, earthquakes, and floods.


By choosing a high-quality outdoor cabinet air conditioner and following proper maintenance, you can ensure reliable cooling performance and long-term equipment protection.


Previous: 
Next: 

Consult Your Cytech Experts

Consult Your Cytech Experts
PROUDCTS
SUPPORT
QUICK LINKS
CONTACT US
    info@cytech.org.cn
   +86 13775296911
   weidun2013
    #5 Fuling Road, Zhonglou district, Changzhou, Jiangsu, China
COPYRIGHT © 2023 CHANGZHOU CHEN TONG YUAN COMMUNICATION EQUIPMENT CO.;LTD ALL RIGHTS RESERVED.