Industrial Technology | Experts in Outdoor Enclosures and Thermal Management Solutions
R & D | Production | Sales
You are here: Home » Products » Thermal Management / Cabinet Ac Unit » 220V 60Hz Cabinet Air Conditioner » 300W Outdoor Electrical Cabinet Air Conditioner 1020BTU

300W Outdoor Electrical Cabinet Air Conditioner 1020BTU

Outdoor electrical cabinet air conditioner or electrical panel air conditioner achieves heat absorption refrigeration through compression refrigeration, transferring the heat emitted by the equipment inside the cabinet to the outside of the cabinet in a closed environment. The high temperature, dust and other dirty gases outside the cabinet will not enter the interior, thus solving a series of problems caused by fan heat dissipation. The interior of the cabinet can always maintain an ideal temperature environment of around 30 ℃, effectively ensuring the stability of electronic equipment.

◆AC220V 60HZ power input
◆300W cooling capacity (optional configured with heater)
◆High efficiency rotary compressor:Reliable & energy saving
◆LED display:Parameters setting and operation display
◆IP55 High protection level:Application in outdoors perfectly
◆Wide operating temperature range:Adapt to all conditions
  • AC103-2/A03NA1E

  • Cytech

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

300W Outdoor Electrical Cabinet Air Conditioner 1020BTU Product Video




300W Outdoor Electrical Cabinet Air Conditioner 1020BTU Certificate




300W Outdoor Electrical Cabinet Air Conditioner 1020BTU Introduction


Outdoor electrical cabinet air conditioner or electrical panel air conditioner is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.



300W Outdoor Electrical Cabinet Air Conditioner 1020BTU Specifications


1.Technical parameter of Outdoor Electrical Cabinet Air Conditioner


Name Outdoor Electrical Cabinet Air Conditioner
Model AC103-2/A03NA1E
Main power supply 1~220VAC±15% 60Hz 1 phase
Cooling capacity(Rated) 300W@L35/L35
Power consumption(Rated) 170W@L35/L35
Heating capacity(optional) 500W
Air flow 100m3/h
Cooling current (rated/Max.) 0.8A/1.4A
Work temp. range -40℃~+55℃
Noise 60dB(A)
IP Grade IP55,NEMA 4,NEMA 4X
Net Weight 25KG
Refrigerant R134a

Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃



2. Thermal cycle and air flow of Outdoor Electrical Cabinet Air Conditioner


Outdoor Electrical Cabinet Air Conditioner Cooling Princple: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.


outdoor cabinet air conditioner cycle



300W Outdoor Electrical Cabinet Air Conditioner 1020BTU Features


◆Outdoor Electrical Cabinet Air Conditioner also can keep the dust and heat outside the cabinet,avoiding problems from using fan;

◆The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;

◆Compact structure ,reasonable design and easy maintenance;

◆Digital temperature controller and high precision of temperature control;

◆The Outdoor Electrical Cabinet Air Conditioner heating function and the hydrogen function is optional;

◆Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;

◆Dry contact alarm output,NO/NC optional;

◆LED display, all the settings can changed at the field

◆Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);

◆Fit for harsh condition (T3), R134a refrigerant .



300W Outdoor Electrical Cabinet Air Conditioner 1020BTU Flexibility


Outdoor Electrical Cabinet Air Conditioner Cooling capacity ranges from 300w to 5000w

Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V

Outdoor Electrical Cabinet Air Conditioner is widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.

Remote monitoring system supported, communication protocol is RS485



More option for outdoor electrical cabinet air conditioner


1.220VAC 50HZ power outdoor electrical cabinet air conditioner



Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Outdoor electrical cabinet air conditioner CYAC103-2 220VAC 50Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Outdoor electrical cabinet air conditioner CYAC104-2 220VAC 50Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Outdoor electrical cabinet air conditioner CYAC105-2 220VAC 50Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Outdoor electrical cabinet air conditioner CYAC110-2 220VAC 50Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Outdoor electrical cabinet air conditioner CYAC112-2 220VAC 50Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Outdoor electrical cabinet air conditioner CYAC113-2 220VAC 50Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Outdoor electrical cabinet air conditioner CYAC115-2 220VAC 50Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
Outdoor electrical cabinet air conditioner CYAC120-2 220VAC 50Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
Outdoor electrical cabinet air conditioner CYAC125-2 220VAC 50Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
Outdoor electrical cabinet air conditioner CYAC130-2 220VAC 50Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
Outdoor electrical cabinet air conditioner CYAC135-2 220VAC 50Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63
Outdoor electrical cabinet air conditioner CYAC150-2 220VAC 50Hz 5000 17000 2000 IP55,NEMA 4, NEMA 4X 2000 2300 R134a 63



2.220VAC 60HZ power outdoor electrical cabinet air conditioner



Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Outdoor electrical cabinet air conditioner CYAC103-2 220VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Outdoor electrical cabinet air conditioner CYAC104-2 220VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Outdoor electrical cabinet air conditioner CYAC105-2 220VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Outdoor electrical cabinet air conditioner CYAC110-2 220VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Outdoor electrical cabinet air conditioner CYAC112-2 220VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Outdoor electrical cabinet air conditioner CYAC113-2 220VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Outdoor electrical cabinet air conditioner CYAC115-2 220VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63
Outdoor electrical cabinet air conditioner CYAC120-2 220VAC 60Hz 2000 6800 745 IP55,NEMA 4, NEMA 4X 1000 500 R134a 63
Outdoor electrical cabinet air conditioner CYAC125-2 220VAC 60Hz 2500 8500 846 IP55,NEMA 4, NEMA 4X 2000 560 R134a 63
Outdoor electrical cabinet air conditioner CYAC130-2 220VAC 60Hz 3000 10200 1240 IP55,NEMA 4, NEMA 4X 2000 720 R134a 63
Outdoor electrical cabinet air conditioner CYAC135-2 220VAC 60Hz 3500 11900 1360 IP55,NEMA 4, NEMA 4X 2000 1250 R134a 63




3.110V 60HZ power outdoor electrical cabinet air conditioner



Name Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA)
Outdoor electrical cabinet air conditioner CYAC103-2 110VAC 60Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56
Outdoor electrical cabinet air conditioner CYAC104-2 110VAC 60Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56
Outdoor electrical cabinet air conditioner CYAC105-2 110VAC 60Hz 500 1700 280 IP55,NEMA 4, NEMA 4X 500 120 R134a 56
Outdoor electrical cabinet air conditioner CYAC110-2 110VAC 60Hz 1000 3400 430 IP55,NEMA 4, NEMA 4X 1000 230 R134a 62
Outdoor electrical cabinet air conditioner CYAC112-2 110VAC 60Hz 1200 4080 498 IP55,NEMA 4, NEMA 4X 1000 240 R134a 62
Outdoor electrical cabinet air conditioner CYAC113-2 110VAC 60Hz 1300 4440 532 IP55,NEMA 4, NEMA 4X 1000 260 R134a 63
Outdoor electrical cabinet air conditioner CYAC115-2 110VAC 60Hz 1500 5100 600 IP55,NEMA 4, NEMA 4X 1000 300 R134a 63




Other Outdoor Electrical Cabinet Air Conditioner 



Name Specification
Air conditioner AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W.
Heat exchanger DC48V,40W/K-200W/K
Combined air conditioner & heat exchanger

AC220V 50HZ and DC48V

1500W&80W/K

TEC DC48V, 200W-1200W
Fan AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V




How to Choose an Outdoor Electrical Cabinet Air Conditioner?


Choosing the right Outdoor Electrical Cabinet Air Conditioner requires careful consideration of several critical factors to ensure that it meets the specific needs of your equipment and the environment. Whether for industrial electrical cabinet air conditioners or air conditioning for electrical panels, here are the key aspects to evaluate.


1. Acceptable Temperature Range for Your Equipment

Every piece of electrical equipment has an optimal temperature range for performance. The electrical panel air conditioning units should be capable of maintaining this range by efficiently removing heat. If the temperature exceeds this range, it could result in equipment damage or failure.


2. Heat Load of Equipment

Each electrical panel or cabinet generates a certain amount of heat depending on the equipment inside. The industrial electrical cabinet air conditioner must be sized to handle the total heat load of the equipment. Underestimating this can lead to insufficient cooling, impacting the performance and lifespan of the equipment.


3. Highest Local Ambient Temperature

The local climate plays a significant role in the performance of your outdoor electrical cabinet air conditioner. The air conditioning system must be able to function effectively under the highest expected ambient temperatures. Ensure that the unit is designed to handle the temperature extremes of the installation environment.


4. Noise Level

In some installations, noise can be a critical factor. Air conditioning for electrical panels in sensitive areas requires a cooling unit that operates at a low noise level to avoid disturbing nearby operations or meeting noise regulation standards.


5. Future Expansion

If you anticipate adding more equipment to your electrical panel or cabinet in the future, consider selecting an air conditioning unit with the capacity to accommodate potential heat load increases. Planning for future expansion ensures that the cooling system remains effective as the load grows.

By carefully evaluating these factors, you can choose a cabinet climate control system that ensures reliable, efficient operation for both the equipment and the environment.



Normative Standards for Outdoor Electrical Cabinet Air Conditioners

Adhering to relevant standards guarantees that your outdoor electrical cabinet air conditioner meets safety, performance, and environmental compliance. Key standards include:

  • GB 4208: Enclosure Protection Class

  • GB 4706.1: Safety of Household and Similar Electrical Appliances

  • GB 9237-2001: Safety Requirements for Mechanical Refrigerating Systems

  • GB/T 17626.8: Electromagnetic Compatibility - Testing and Measurement Techniques - Power Frequency Magnetic Field Immunity Test



Troubleshooting and Fault Analysis


Sometimes, issues arise with your electrical panel air conditioning units. Here's a brief guide to help you troubleshoot common problems:


Fault: Air Conditioner Is Not Working, but the Cabinet Temperature Is Too High


Possible Causes:

  • Power failure or no power

  • Cooling set temperature is higher than the cabinet temperature

  • System fault

Solutions:

  • Check the power supply and the electrical circuit

  • Adjust the cooling temperature according to needs

  • Contact professional maintenance if the problem persists


Fault: Air Conditioner Running, but Cooling Effect Is Poor

Possible Causes:

  • Cooling capacity mismatch with the load

  • Ambient temperature too high

  • System fault

Solutions:

  • Choose an air conditioner with a higher cooling capacity

  • Ensure that the machine operates within the correct temperature range

  • Contact professional maintenance for further diagnosis


Fault: Air Conditioner Stops Suddenly

Possible Causes:

  • Cabinet temperature exceeds or matches the cooling set temperature

  • System fault

Solutions:

  • Adjust the cooling temperature settings

  • Contact professional maintenance for system inspection



Warranty Information


The typical warranty period for outdoor electrical cabinet air conditioners is 12 months from the product's operational start date or up to 18 months from delivery, depending on the agreement. During the warranty period, faults caused by manufacturing defects will be repaired free of charge. However, warranty coverage does not apply under the following circumstances:


  1. Out of the warranty period

  2. Missing product label

  3. Faults caused by abnormal conditions, incorrect installation, or improper use

  4. Damage caused by external equipment or software

  5. Unauthorized modifications or repairs

  6. Force majeure events such as fires, floods, or earthquakes


Understanding the warranty terms ensures that you maintain a reliable cooling system throughout the product's lifespan.


Previous: 
Next: 

Consult Your Cytech Experts

Consult Your Cytech Experts
PROUDCTS
SUPPORT
QUICK LINKS
CONTACT US
    info@cytech.org.cn
   +86 13775296911
   weidun2013
    #5 Fuling Road, Zhonglou district, Changzhou, Jiangsu, China
COPYRIGHT © 2023 CHANGZHOU CHEN TONG YUAN COMMUNICATION EQUIPMENT CO.;LTD ALL RIGHTS RESERVED.