AC113-2
CY TECH
Telecom, Battery, Integrated
IP 55, IP 65
Half-embeded Mount, Door Mount
1300W/4436BTU
| Availability: | |
|---|---|
Product Description
Designed for industrial enclosures, the AC 1300W Enclosure Air Conditioner delivers precise thermal management to protect sensitive electronics in telecom and energy cabinets. This industrial enclosure air conditioner ensures continuous thermal protection and stable operation even under harsh environmental conditions.
Its compact, corrosion-resistant housing and low-noise operation make it ideal for remote industrial stations, telecom towers, and battery enclosures, offering high reliability with minimal maintenance.
Equipped with an intelligent control system, the AC 1300W dynamically adjusts cooling output, monitors performance, and triggers alarms to prevent overheating, providing long-term protection for electronics in industrial enclosures.
High-efficiency enclosure air conditioner AC compressor
LED digital display for real-time enclosure AC monitoring
RS485 / Modbus-RTU interface for remote enclosure management
Over-temperature alarm and fault protection for critical electronics
Closed-loop cooling: prevents dust and moisture entry
Optional heater for low-temperature environments
Anti-corrosion design suitable for coastal and industrial enclosures
Self-diagnosis and system monitoring for industrial enclosure thermal management
Long service life with minimal maintenance
Quick side-mount or door-mount installation for battery and control cabinets
Name | Enclosure Air Conditioner AC 1300 W |
Model | AC113-2 |
Main power supply | 1~220VAC±15% 50Hz 1 phase |
Cooling capacity(Rated) | 1300W@L35/L35 |
Power consumption(Rated) | 532W@L35/L35 |
Heating capacity(optional) | 1000W |
Air flow | 260m3/h |
Cooling current (rated/Max.) | 14.8A/19.0A |
Work temp. range | -40℃~+55℃ |
Noise | 60dB(A) |
IP Grade | IP55,NEMA 4,NEMA 4X |
Net Weight | 31KG |
Refrigerant | R134a |
Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃
Industrial Enclosure Air Conditioner Cooling Princple : the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.

Application
Enclosure air conditioner for telecom BTS outdoor cabinets
Cooling for 4G/5G base station equipment cabinets
Battery energy storage systems (BESS) and power distribution cabinets
Industrial automation & control panels
Pole-mounted enclosures for traffic, ITS, CCTV
Remote industrial shelters requiring reliable enclosure AC solutions
Options
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
220VAC 50Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
220VAC 50Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
220VAC 50Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
220VAC 50Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
220VAC 50Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
220VAC 50Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
220VAC 50Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 | |
CYAC120-2 | 220VAC 50Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 |
220VAC 50Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 | |
220VAC 50Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 | |
220VAC 50Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 | |
220VAC 50Hz | 5000 | 17000 | 2000 | IP55,NEMA 4, NEMA 4X | 2000 | 2300 | R134a | 63 |
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
220VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
220VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
220VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
220VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
220VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
220VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
220VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 | |
220VAC 60Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 | |
220VAC 60Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 | |
220VAC 60Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 | |
220VAC 60Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
110VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
110VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
110VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
110VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
110VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
110VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
110VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
to be continued ,please contact with your sales expert.
Name | Specification |
| |
| |
| |
| |
|
Advantages&Why?
Whether in industrial plants or outdoor telecom sites, our AC units maintain stable temperatures, safeguarding critical electronics.
Prevents overheating, condensation, and equipment downtime with a trusted, high-performance cooling system.
Reduce operational costs without compromising on reliability, thanks to smart design and low energy consumption.
Decades years of experience
Global supply capability
Customized cooling solutions
Fast delivery and technical support
Widely used in telecom, utilities, transportation, and energy storage industries
Cooling capacity ranges from 300w to 5000w
Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V
Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.
Remote monitoring system supported, communication protocol is RS485

Our engineering team can recommend the right model based on:
Cabinet size
Heat load
Installation method
Environment
Voltage requirements
Contact us for datasheets, drawings, pricing, or OEM/ODM solutions.