Product Description
The AC 2500W Enclosure Air Conditioning system is designed for high-heat load industrial enclosures, delivering consistent cooling for energy-intensive cabinets and automation systems. This high-capacity enclosure air conditioning solution ensures stable internal climates and protects critical electronics under continuous operation.
Its robust, corrosion-resistant structure and low-noise operation make it ideal for large energy storage cabinets, industrial control panels, and telecom enclosures. The efficient cooling design supports sustained performance even in demanding conditions.
With an intelligent control system, the AC 2500W high capacity enclosure air conditioning automatically regulates cooling output, monitors system health, and issues alerts to prevent overheating, providing continuous protection for high-heat enclosures.
High-efficiency AC compressor for industrial enclosure air conditioning
LED display for real-time enclosure thermal monitoring
RS485 / Modbus-RTU interface for remote enclosure AC control
Over-temperature alarm and fault protection for critical equipment
Closed-loop cooling: dust and moisture resistant
Optional heater for low-temperature operation
Anti-corrosion design suitable for coastal and industrial regions
Self-diagnosis and real-time monitoring for high-heat enclosure protection
Long service life with minimal maintenance
Quick installation for side-mount or door-mount industrial enclosures
Name | Enclosure Air Conditioning AC 2500 W |
Model | AC125-2 |
Main power supply | 1~220VAC±15% 50Hz 1 phase |
Cooling capacity(Rated) | 2500W@L35/L35 |
Power consumption(Rated) | 900W@L35/L35 |
Heating capacity(optional) | 1000W |
Air flow | 560m3/h |
Cooling current (rated/Max.) | 14.8A/19.0A |
Work temp. range | -40℃~+55℃ |
Noise | 63dB(A) |
IP Grade | IP55,NEMA 4,NEMA 4X |
Net Weight | 37KG |
Refrigerant | R134a |
Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃
Industrial Enclosure Air Conditioning Cooling Princple : the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly.

Application
Energy storage systems (BESS)
Large-scale industrial cabinets
Power distribution and automation systems
Telecom 4G/5G base station cabinets
Outdoor industrial shelters
Remote sites requiring high-load enclosure cooling
Options
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
220VAC 50Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
220VAC 50Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
220VAC 50Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
220VAC 50Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
220VAC 50Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
220VAC 50Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
220VAC 50Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 | |
CYAC120-2 | 220VAC 50Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 |
220VAC 50Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 | |
220VAC 50Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 | |
220VAC 50Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 | |
220VAC 50Hz | 5000 | 17000 | 2000 | IP55,NEMA 4, NEMA 4X | 2000 | 2300 | R134a | 63 |
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
220VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
220VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
220VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
220VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
220VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
220VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
220VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 | |
220VAC 60Hz | 2000 | 6800 | 745 | IP55,NEMA 4, NEMA 4X | 1000 | 500 | R134a | 63 | |
220VAC 60Hz | 2500 | 8500 | 846 | IP55,NEMA 4, NEMA 4X | 2000 | 560 | R134a | 63 | |
220VAC 60Hz | 3000 | 10200 | 1240 | IP55,NEMA 4, NEMA 4X | 2000 | 720 | R134a | 63 | |
220VAC 60Hz | 3500 | 11900 | 1360 | IP55,NEMA 4, NEMA 4X | 2000 | 1250 | R134a | 63 |
Model | Voltage | Nominal cooling capacity(W) (L35/L35) | Nominal cooling capacity(Btu/hr) (L35/L35) | Power consumption(W)(L35/L35) | IP Grade | Heater (W)(option) | Internal air flow (m3/h) | Refrigerant | Noise (dbA) |
110VAC 60Hz | 300 | 1020 | 170 | IP55,NEMA 4, NEMA 4X | 500 | 100 | R134a | 56 | |
110VAC 60Hz | 400 | 1360 | 215 | IP55,NEMA 4, NEMA 4X | 500 | 110 | R134a | 56 | |
110VAC 60Hz | 500 | 1700 | 280 | IP55,NEMA 4, NEMA 4X | 500 | 120 | R134a | 56 | |
110VAC 60Hz | 1000 | 3400 | 430 | IP55,NEMA 4, NEMA 4X | 1000 | 230 | R134a | 62 | |
110VAC 60Hz | 1200 | 4080 | 498 | IP55,NEMA 4, NEMA 4X | 1000 | 240 | R134a | 62 | |
110VAC 60Hz | 1300 | 4440 | 532 | IP55,NEMA 4, NEMA 4X | 1000 | 260 | R134a | 63 | |
110VAC 60Hz | 1500 | 5100 | 600 | IP55,NEMA 4, NEMA 4X | 1000 | 300 | R134a | 63 |
to be continued ,please contact with your sales expert.
Name | Specification |
| |
| |
| |
| |
|
Advantages&Why?
Whether in industrial plants or outdoor telecom sites, our AC units maintain stable temperatures, safeguarding critical electronics.
Prevents overheating, condensation, and equipment downtime with a trusted, high-performance cooling system.
Reduce operational costs without compromising on reliability, thanks to smart design and low energy consumption.
Decades years of experience
Global supply capability
Customized cooling solutions
Fast delivery and technical support
Widely used in telecom, utilities, transportation, and energy storage industries
Cooling capacity ranges from 300w to 5000w
Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V
Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.
Remote monitoring system supported, communication protocol is RS485

Our engineering team can recommend the right model based on:
Cabinet size
Heat load
Installation method
Environment
Voltage requirements
Contact us for datasheets, drawings, pricing, or OEM/ODM solutions.