This thermal management system is  perfect for battery storage cabinets,telecom cabinets etc offering precise temperature control to maximize battery performance and longevity. Its energy-saving technology reduces operational costs, while its compact design fits seamlessly into your setup. Features include smart temperature monitoring, corrosion-resistant materials, and quiet operation.

◆ AC220V 50HZ power input
◆ 2500W 8500BTU/H cooling capacity (optional configured with heater)
◆ High efficiency rotary compressor:Reliable & energy saving
◆ LED display:Parameters setting and operation display
◆ IP55 High protection level:Application in outdoors perfectly
◆ Wide operating temperature range:Adapt to all conditions
 
  • AC125-2/A25NA1E

  • Cytech

  • IP 55

  • Wall Mount

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

Production video for Thermal Management of enclosure ac for telecom cabinets   



Why Thermal Management is Crucial for Telecom Cabinets?


Thermal management is crucial for telecom cabinets because it directly impacts the performance, reliability, and longevity of the sensitive electronic equipment housed within them. Please find more key reasons why effective thermal management is essential from our Blog.



Thermal management for telecom cabinets Certificate


Effective Thermal Management for Telecom Cabinets



Introduction of Thermal Management product for telecom cabinets


Outdoor cabinet ac is actively cooling by compressor ,it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet,avoiding problems from using fan. The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system.

 


2500W enclousre aircon Thermal Management for Outdoor Cabinets Specifications

 

1) Technical parameter of enclosure ac thermal management system

 

Name

Enclosure ac

Model

AC125-2/A25NA1E

Main power supply

1~220VAC±15% 50Hz 1 phase

Cooling capacity(Rated)

2500W@L35/L35                 8500BTU

Power consumption(Rated)

846W@L35/L35

Heating capacityoptional

2000W

Air flow

560m3/h

Cooling current (rated/Max.)

3.8A/5.0A

Work temp. range

-40℃~+55℃

Noise

65dB(A)

IP Grade

IP55,NEMA 4,NEMA 4X

Net Weight

37KG

Refrigerant

R134a


Note:@L35/L35 is Internal temperature 35℃, ambient temperature 35℃



2) Thermal cycle and air flow of thermal management systems.


Thermal managment systems of Enclosure AC Cooling Principle: the high-pressure refrigerant liquid in the system enters the evaporator and evaporates to absorb heat of the air in the cabinet, so the air is cooled, and the refrigerant that evaporates into gas in the evaporator is inhaled by the compressor and compressed into the high-pressure and high-temperature refrigerant gas, which enters the condenser and cooled to refrigerant liquid, and then re-enters the evaporator to cool the indoor air, and circulates accordingly

 

outdoor cabinet air conditioner cycle

 

Thermal Management for Cabinets Features

 

◆Thermal management system  also can keep the dust and heat outside the cabinet,avoiding problems from using fan; 

The temperature inside the cabinet can be maintained at an ideal temperature for electrical components which effectively guarantee the stability of the electronic equipment and improves the reliability of the whole system;

Compact structure ,reasonable design and easy maintenance;

Digital temperature controller and high precision of temperature control;

The heating function and the hydrogen function is optional;

Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;

Dry contact alarm output,NO/NC optional;

LED display, all the settings can changed at the field

Multiple self-protection design & visible monitoring interface, RS485 communication port (MODBUS-RTU);

Fit for harsh condition (T3), R134a refrigerant .

 

Thermal Management for Cabinets Flexibility

 

Cooling capacity ranges from 300w to 5000w

Voltage range :AC220V 50HZ,AC220V 60HZ,60HZ , AC110V60HZ ,DC48V

Widely used for outdoor telecom cabinets ,battery cabinets,elecric cabinets and industry control cabinets etc.

Remote monitoring system supported, communication protocol is RS485.



More options for thermal managment


1) 220VAC 50HZ power enclosure ac


 

Name

Model

Voltage

Nominal cooling capacity(W) (L35/L35)

Nominal cooling capacity(Btu/hr) (L35/L35)

Power consumption(W)(L35/L35)

IP Grade

Heater (W)(option)

Internal air flow (m3/h)

Refrigerant

Noise (dbA)

Enclosure AC

CYAC103-2

220VAC 50Hz

300

1020

170

IP55,NEMA 4, NEMA 4X

500

100

R134a

56

Enclosure AC

CYAC104-2

220VAC 50Hz

400

1360

215

IP55,NEMA 4, NEMA 4X

500

110

R134a

56

Enclosure AC

CYAC105-2

220VAC 50Hz

500

1700

280

IP55,NEMA 4, NEMA 4X

500

120

R134a

56

Enclosure AC

CYAC110-2

220VAC 50Hz

1000

3400

430

IP55,NEMA 4, NEMA 4X

1000

230

R134a

62

Enclosure AC

CYAC112-2

220VAC 50Hz

1200

4080

498

IP55,NEMA 4, NEMA 4X

1000

240

R134a

62

Enclosure AC

CYAC113-2

220VAC 50Hz

1300

4440

532

IP55,NEMA 4, NEMA 4X

1000

260

R134a

63

Enclosure AC

CYAC115-2

220VAC 50Hz

1500

5100

600

IP55,NEMA 4, NEMA 4X

1000

300

R134a

63

Enclosure AC

CYAC120-2

220VAC 50Hz

2000

6800

745

IP55,NEMA 4, NEMA 4X

1000

500

R134a

63

Enclosure AC

CYAC125-2

220VAC 50Hz

2500

8500

846

IP55,NEMA 4, NEMA 4X

2000

560

R134a

63

Enclosure AC

CYAC130-2

220VAC 50Hz

3000

10200

1240

IP55,NEMA 4, NEMA 4X

2000

720

R134a

63

Enclosure AC

CYAC135-2

220VAC 50Hz

3500

11900

1360

IP55,NEMA 4, NEMA 4X

2000

1250

R134a

63

Enclosure AC

CYAC150-2

220VAC 50Hz

5000

17000

2000

IP55,NEMA 4, NEMA 4X

2000

2300

R134a

63

 


2)220VAC 60HZ power thermal management 



Name

Model

Voltage

Nominal cooling capacity(W) (L35/L35)

Nominal cooling capacity(Btu/hr) (L35/L35)

Power consumption(W)(L35/L35)

IP Grade

Heater (W)(option)

Internal air flow (m3/h)

Refrigerant

Noise (dbA)

Enclosure AC

CYAC103-2

220VAC 60Hz

300

1020

170

IP55,NEMA 4, NEMA 4X

500

100

R134a

56

Enclosure AC

CYAC104-2

220VAC 60Hz

400

1360

215

IP55,NEMA 4, NEMA 4X

500

110

R134a

56

Enclosure AC

CYAC105-2

220VAC 60Hz

500

1700

280

IP55,NEMA 4, NEMA 4X

500

120

R134a

56

Enclosure AC

CYAC110-2

220VAC 60Hz

1000

3400

430

IP55,NEMA 4, NEMA 4X

1000

230

R134a

62

Enclosure AC

CYAC112-2

220VAC 60Hz

1200

4080

498

IP55,NEMA 4, NEMA 4X

1000

240

R134a

62

Enclosure AC

CYAC113-2

220VAC 60Hz

1300

4440

532

IP55,NEMA 4, NEMA 4X

1000

260

R134a

63

Enclosure AC

CYAC115-2

220VAC 60Hz

1500

5100

600

IP55,NEMA 4, NEMA 4X

1000

300

R134a

63

Enclosure AC

CYAC120-2

220VAC 60Hz

2000

6800

745

IP55,NEMA 4, NEMA 4X

1000

500

R134a

63

Enclosure AC

CYAC125-2

220VAC 60Hz

2500

8500

846

IP55,NEMA 4, NEMA 4X

2000

560

R134a

63

Enclosure AC

CYAC130-2

220VAC 60Hz

3000

10200

1240

IP55,NEMA 4, NEMA 4X

2000

720

R134a

63

Enclosure AC

CYAC135-2

220VAC 60Hz

3500

11900

1360

IP55,NEMA 4, NEMA 4X

2000

1250

R134a

63

 


3)110V 60HZ power enclosure ac of thermal management system


Name

Model

Voltage

Nominal cooling capacity(W) (L35/L35)

Nominal cooling capacity(Btu/hr) (L35/L35)

Power consumption(W)(L35/L35)

IP Grade

Heater (W)(option)

Internal air flow (m3/h)

Refrigerant

Noise (dbA)

Enclosure AC

CYAC103-2

110VAC 60Hz

300

1020

170

IP55,NEMA 4, NEMA 4X

500

100

R134a

56

Enclosure AC

CYAC104-2

110VAC 60Hz

400

1360

215

IP55,NEMA 4, NEMA 4X

500

110

R134a

56

Enclosure AC

CYAC105-2

110VAC 60Hz

500

1700

280

IP55,NEMA 4, NEMA 4X

500

120

R134a

56

Enclosure AC

CYAC110-2

110VAC 60Hz

1000

3400

430

IP55,NEMA 4, NEMA 4X

1000

230

R134a

62

Enclosure AC

CYAC112-2

110VAC 60Hz

1200

4080

498

IP55,NEMA 4, NEMA 4X

1000

240

R134a

62

Enclosure AC

CYAC113-2

110VAC 60Hz

1300

4440

532

IP55,NEMA 4, NEMA 4X

1000

260

R134a

63

Enclosure AC

CYAC115-2

110VAC 60Hz

1500

5100

600

IP55,NEMA 4, NEMA 4X

1000

300

R134a

63


Thermal Management system selection for telecom cabinets


Name

Specification

Air conditioner

AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V, cooling capacity from 300W-5000W.

Heat exchanger

DC48V,40W/K-200W/K

Combined air conditioner & heat exchanger

AC220V 50HZ and DC48V

1500W&80W/K

TEC

DC48V, 200W-1200W

Fan

AC220V 50HZ,AC220V 60HZ,AC110V 60HZ or DC48V

 


How to Choose the Right Thermal Management for telecom cabinets?


Selecting the appropriate cooling untis (Industrial Enclosure Air Conditioner) is crucial for ensuring the efficient operation and longevity of your equipment, particularly in environments where temperature control is essential. By focusing on key factors such as the acceptable temperature range, heat load, local ambient temperature, noise level, and future expansion, you can make a well-informed decision. Here’s a deeper look into these factors:



1. Acceptable Temperature Range for Your Equipment


Every piece of equipment has an optimal operating temperature range. Understanding this range is vital to prevent overheating or underperformance. An electrical enclosure cooling system must maintain the interior temperature within this range to ensure the longevity and reliability of your equipment.



2. Heat Load of Equipment


The heat generated by your equipment directly impacts the cooling requirements. A higher heat load demands a more powerful thermal management system. By calculating the total heat dissipation, you can select a thermal management solution that matches the cooling capacity required.



3. The Highest Local Ambient Temperature


Local environmental conditions can influence the performance of the enclosure cooling system. The thermal management system should be capable of handling the highest temperature expected in the operating environment, especially in industries where high external temperatures are common.



4. Noise Level


Noise generated by the thermal management cooling units can be a concern in environments requiring a quiet atmosphere. Consider the noise specifications of the industrial enclosure air conditioner to ensure it does not interfere with the work environment.



5. Future Expansion


As your system grows or new equipment is added, it’s essential to account for future needs. Choosing thermal management system for cabinet with scalability options can help accommodate increased heat loads as your equipment evolves.


By evaluating these considerations, you can ensure that your  meets the specific demands of your equipment and environmental conditions.



Normative Standards for Thermal Management for telecom cabinets


When selecting and installing an industrial enclosure air conditioner, adherence to national standards ensures safety and efficiency. Key standards include:


  • GB 4208 – Enclosure Protection Class

  • GB 4706.1 – Safety of Household and Similar Electrical Appliances

  • GB9237-2001 – Mechanical Refrigerating Systems for Cooling and Heating

  • GB/T 17626.8 – Electromagnetic Compatibility Testing (Power Frequency Magnetic Field Immunity Test)


These standards govern the safety, efficiency, and electromagnetic compatibility of the electrical enclosure cooling system, helping ensure proper installation and operation.



Fault Analysis and Solutions for thermal management system.


Despite careful selection and installation, faults may still occur in the Enclosure AC. Here are some common issues and solutions:


  1. Cabinet Temperature Too High, Air Conditioner Not Working

    • Causes: Power failure, incorrect cooling set temperature, system fault

    • Solutions: Check power supply and electrical circuit, adjust cooling temperature, or contact professional maintenance.


  2. Air Conditioner Running but Cooling Effect is Poor

    • Causes: Mismatch between cooling capacity and heat load, high ambient temperature, system fault

    • Solutions: Add or replace the air conditioner based on load requirements, ensure the machine is used within the correct temperature range, or contact professional maintenance.


  3. Machine Stopping Suddenly, Normal Electrical System

    • Causes: Cabinet temperature greater than or equal to the set cooling temperature, system fault

    • Solutions: Adjust the cooling temperature settings, or consult with maintenance professionals.



Warranty Coverage and Considerations for Thermal Management of telecom cabinet


The cooling system typically comes with a 12-month warranty from the product's running time or up to 18 months from delivery, depending on the agreement. Warranty covers product quality issues, but the following conditions are not covered:


  1. Out of Warranty Period

  2. Missing Product Label

  3. Fault Due to Abnormal Conditions or Improper Installation

  4. Damage Caused by User Modifications

  5. Force Majeure Events (e.g., fires, floods)


Ensuring that the thermal management system is maintained according to manufacturer specifications is key to retaining warranty coverage.

By understanding these critical factors and adhering to the standards and maintenance protocols, you can choose thermal management for telecom cabinet  that will ensure the efficiency and reliability of your industrial equipment.

Previous: 
Next: 

Consult Your Cytech Experts

Consult Your Cytech Experts
PROUDCTS
SUPPORT
QUICK LINKS
CONTACT US
    info@cytech.org.cn
   +86 13775296911
   weidun2013
    #5 Fuling Road, Zhonglou district, Changzhou, Jiangsu, China
COPYRIGHT © 2023 CHANGZHOU CHEN TONG YUAN COMMUNICATION EQUIPMENT CO.;LTD ALL RIGHTS RESERVED.